Завод "Оконная Мануфактура"
Производство и продажа светопрозрачных конструкций из ПВХ и алюминиевых профилей
-
Технический центр "Пожтехник"
Поставка противопожарного оборудования, предоставление услуг по техническому обслуживанию первичных средств пожаротушения
-
Псковтехгаз - Промышленные газы
Производство промышленных, специальных и медицинских газов
-
"Всё для сварки"
Сеть специализированных магазинов
-
Псковтехгаз - Криогенные технологии
Разработка, производство и обслуживание криогенного оборудования

Cryogenic pump unit ANK (АНК) 10.20
INTENDED USE
ANK-VV-10.20 (АНК-ВВ-10.20) is designed for pumping liquefied air separation products (oxygen, nitrogen, argon) and natural gas.
The pump unit is used as part of gasification plants:
for filling cylinders and other buffer tanks of oil and gas, chemical, metallurgical, automotive industry;
in other processes where technical and medical gases are used.
Гарантия
12 месяцев
ADVANTAGES:
1. After-warranty service.
2. There is no discharge of the product into the atmosphere during refrigeration, since the vapor-liquid mixture formed in this case is displaced from the cylinder group by the liquid product back to the reservoir via the "gas connection" pipeline.
3. The pump unit does not need to be purged after short idle periods between refueling of the batches of cylinders.
4. The losses of the cryogenic product are minimized, since by using the vacuum insulation of the cylinder group, heat flows from the environment are reduced.
5. The pump unit can work with horizontal and vertical cryogenic tanks.
SPECIFICATIONS:
Maximum Performance (in oxygen), l/min (m³/h) |
10 (495) |
Working pressure, MPa |
20 |
Maximum discharge pressure, MPa |
22.2 |
Power consumption, kW |
8.0 |
Dimensions L xDxH, mm |
1,500x720x650 |
Weight, kg |
250 |
DIMENSIONAL DRAWING:
STANDARD ANK (АНК) DELIVERY:
1. Frame (1). 2. Pulsations compensator (2) with a safety valve. 3. Discharge pipeline (3) with a check valve. 4. Cylinder-piston group (4) with vacuum insulation. 5. Motion mechanism (5). |
6. V-belt drive (6). 7. Electric motor (7). 8. Suction chamber safety valve (8). 9. Set of flexible metal hoses for connection to the tank. 10. Set of spare parts. 11. Operational and technical documentation. |
OPTION 1: EXECUTION
By default, the output of the discharge line is to the right.
The left execution shall be stipulated in the technical order by the "Customer".
OPTION 2: SENSORS
Name |
Intended use |
Temperature sensor in the discharge line |
Protection from "dry running". |
Temperature sensor in the "gas connection" line |
Control of the cooling process. Start authorization. |
Temperature control sensor in the "liquid to pump" line |
Control of the cooling process. |
Temperature sensor in the collar area |
Collar unit control to prevent gas leakage. |
Pressure sensor in the discharge line |
Overpressure protection. |
OPTION 3: FREQUENCY CONVERTER
Used to smoothly control the capacity of the pump unit.
OPTION 4: SWITCHBOARD
It monitors and controls the ANK (АНК) operation. Can include elements of control and management of other systems.
SWITCHBOARD TECHNICAL CHARACTERISTICS:
Rated power, kW |
11 |
Voltage, V |
380 |
Curren t frequency, Hz |
50 |
Ambient temperature, С |
U1 (У1) |
Protection |
IP55 |
Material |
Steel |
Coating |
Powder coating |
TYPICAL CONDITIONS*
50% advance payment within 5 business days after the invoice;
50% advance payment within 3 business days after receiving notification of the availability of equipment for shipment.
Delivery time
45 business days after receiving the advance payment.
Change of delivery time
- possible due to late payment by the Buyer, as agreed by the parties;
The manufacturer reserves the right for early delivery of the products if the production happens in May or January.
EXW (Pskov) INCOTERMS-2010
Delivery costs (from Pskov, Russia) and insurance (if necessary) are paid by the Buyer.
12 MONTHS from the date of putting the equipment into operation,
but not more than 18 months from the date of shipment.
Before shipment, each pump shall be tested, the results of such tests shall be recorded in the documentation transmitted to the Buyer.
The warranty does not apply to quick-wear parts.
Service (post-warranty) shall be carried out at the Buyer's request, upon a separate service contract.
The manufacturer reserves the right to use the services of a third party to reduce the costs of the Customer (in case of considerable distance between the place of equipment operation and Pskov (Russia)).
Customs Union Declaration of compliance № RU Д-RU.АВ54.В.00053 dated 08.10.2014 valid until 07.10.2019 inclusive.
Реализованные проекты с этим оборудованием
Услуги
дополнительно-
Experimental and design works
-
Repair, routine maintenance and restoration (renovation) of cryogenic equipment
-
Equipment modernization
-
Installation and commissioning
-
Maintenance of equipment and gas systems in medical institutions
-
Technical support for reservoir check
-
Degassing and crimping of pressure equipment